The technology of IPL and bipolar radio frequency jointly act on the entire corium layer and connective tissue to stimulate the realignment and regrowth of collagens in different depths, and the selective absorption of light by the skin brings about the photothermolysis effect on various pathological tissues of epidermis and corium layer, thus achieving the beauty effect.
The bipolar radio frequency released can lead to high frequency vibration of water molecules in cells at a certain hypodermic depth, the heat 45-60℃ generated from which shrinks the myofibril, tightens the skin and wrinkles. Then the thermal effect generated in the corium layer will reproduce, rearrange, increase and repair the collagens, instantly achieving the effect of skin tightening, permanent wrinkle removal and anti-aging.
Eyebrow tattoo removal: Long wavelengths allow laser light to penetrate more deeply to the corium layer, and heat generated in the hair shaft diffuses to the stem cell and matrix targets to cause desired damage. Due to the short action time (lasting only several nanoseconds), the pigment expands rapidly after absorbing high-energy lasers in an instant, and then cracks into fine granules that are phagocytize by macrophages and then excreted from the body, thus lightening the pigments and whitening the skin.
ApplicationsBasic specification | |||
Screen | 10.4 inch color LCD touch screen | ||
Cooling Way | Water & semi-conductor cooling | ||
Power Supply | 220V/110V ±10% 50Hz/60Hz | ||
E-light system | Nd Yag laser tattoo removal system | ||
Lamp-house | Super intense pulsed light | Laser Type | Q-Switched Nd: YAG laser |
Range of Spectrum | 480-950nm: remove acne | Wavelength | 1064nm&532nm |
530 -950nm: pigmentation treatment | Power | 500W | |
560 -950nm: skin rejuvenation | Pulse energy | 1000mj | |
590-950nm: remove vascular | Duration (WIDTH) | 6ns | |
640 -950nm: remove unwanted hair | Voltage | 500-1000V | |
690-950nm/755-950nm/810-950nm: remove hair (optional) | Pulse Repetition Rate | 1-6Hz | |
RF Frequency | 3MHZ | Indicator light | infrared indicator |
RF Energy | 1-100J/cm3 | Treatment Area | 1mm2 - 7mm2 |
IPL Energy | 1~50J/cm2 | Cooling Method | water cooling&air cooling |
Power supply | 2500W | Independent RF system | |
Size of Spot | Filter handpiece: 12*30mm2, 13*40mm2, 15*50 mm2 | Tripolar RF system | |
Filter fixed handpiece: 8*40mm2, 14*40mm2, 16*50 mm2 | |||
Pulse number | 1~6T | Frequency | 1-40MHz |
Pulse Interval | 1~99ms | Handle of RF | one body RF+ one face RF |
Pulse Width | 0.1~9.9ms | Energy | 5~450J/cm2 |
Discharge interval | 1~4s | Biopolar RF system | |
RF Delay | 1~3s | Cooling control | 0°C~30°C |
Cooling | semi-conductor cooling, water cooling, air cooling | Handle | one handle for Body |
Cooling Temperature | -5~5 °C | Energy | 5~450J |